Delta Electronics InfraSuite Device Master

RISK EVALUATION. Successful exploitation of these vulnerabilities could allow an attacker to remotely execute arbitrary code and obtain plaintext credentials. In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacker to write to any file to any location of the filesystem, which could lead to remote code execution. CVE-2023-46690 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is. In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute code with local administrator privileges. CVE-2023-47207 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is. In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute arbitrary code through a single UDP packet. CVE-2023-39226 has been assigned to this vulnerability. In Delta Electronics InfraSuite Device Master v.1.0.7, A vulnerability exists that allows an unauthenticated attacker to disclose user information through a single UDP packet, obtain plaintext credentials, or perform NTLM relaying. CVE-2023-47279 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is. MITIGATIONS. Delta Electronics recommends updating their software to v1.0.10 or later. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks, recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa. Gov/ics in the technical information paper, ICS-TIP-12-146-01B-Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

This Cyber News was published on www.cisa.gov. Publication date: Thu, 30 Nov 2023 21:55:05 +0000


Cyber News related to Delta Electronics InfraSuite Device Master

Vulnerability Summary for the Week of November 27, 2023 - PrimaryVendor - Product apple - multiple products Description A memory corruption vulnerability was addressed with improved locking. Published 2023-12-01 CVSS Score not yet calculated Source & Patch Info CVE-2023-48842 PrimaryVendor - Product dell - ...
7 months ago Cisa.gov
Delta Electronics InfraSuite Device Master - RISK EVALUATION. Successful exploitation of these vulnerabilities could allow an attacker to remotely execute arbitrary code and obtain plaintext credentials. In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows ...
7 months ago Cisa.gov
Flaws in Delta OT Monitoring Product Can Allow Hackers to Hide Destructive Activities - Critical vulnerabilities in a Delta Electronics operational technology monitoring product can allow hackers to hide destructive activities from the targeted organization's employees. The affected product is Delta's InfraSuite Device Master and the ...
6 months ago Securityweek.com
Delta Dental of California data breach exposed info of 7 million people - Delta Dental of California and its affiliates are warning almost seven million patients that they suffered a data breach after personal data was exposed in a MOVEit Transfer software breach. Delta Dental of California is a dental insurance provider ...
6 months ago Bleepingcomputer.com
Delta Electronics InfraSuite Device Master - RISK EVALUATION. Successful exploitation of this vulnerability could allow remote code execution. Delta Electronics InfraSuite Device Master contains a deserialization of untrusted data vulnerability because it runs a version of Apache ActiveMQ which ...
1 month ago Cisa.gov
Delta Dental says data breach exposed info of 7 million people - Delta Dental of California is warning almost seven million patients that they suffered a data breach after personal data was exposed in a MOVEit Transfer software breach. Delta Dental is a dental insurance provider that covers 85 million people ...
6 months ago Bleepingcomputer.com
MongoDB issues weekend warning of breach The Register - Critical vulnerabilities: The not-patch-Tuesday list. As is usually the case this time of month, the most pressing vulnerabilities of recent days were revealed/patched in Patch Tuesday releases. CVSS 9.8 - So many CVEs: Siemens SIMATIC S7-1500 CPU ...
6 months ago Go.theregister.com
LastPass Enforces 12-Character Master Passwords - Two years after suffering a series of major beaches, LastPass has started implementing stricter password measures for its customers. These include the requirement for all customers to use a master password with at least 12 characters. This measure ...
6 months ago Infosecurity-magazine.com
Dashlane launches passwordless login - Most of us are dreaming of a glorious passwordless future. Today, the company confirmed: Dashlane is the first credential manager to eliminate the Master Password. At least, that feature will only be available to new users. Also: Beyond passwords: 4 ...
6 months ago Zdnet.com
CMDB: Device Visibility for Bank Security - Let us see how a device visibility and control software functions to automatically alert when a rogue or unauthorized device enters your network. Device visibility and control is a cybersecurity concept that refers to the ability to discover, ...
5 months ago Feeds.dzone.com
CVE-2021-47280 - In the Linux kernel, the following vulnerability has been resolved: drm: Fix use-after-free read in drm_getunique() There is a time-of-check-to-time-of-use error in drm_getunique() due to retrieving file_priv->master prior to locking the device's ...
1 month ago Tenable.com
Data Governance: MDM and RDM - Data governance is a framework that is developed through the collaboration of individuals with various roles and responsibilities. These goals may include providing reliable data for business operations, developing accurate analytics to assess ...
6 months ago Feeds.dzone.com
Cooler Master hit by data breach exposing customer information - Computer hardware manufacturer Cooler Master has suffered a data breach after a threat actor breached the company's website and claimed to steal the Fanzone member information of 500,000 customers. Cooler Master is a hardware manufacturer based in ...
1 month ago Bleepingcomputer.com
Cooler Master confirms customer info stolen in data breach - Computer hardware manufacturer Cooler Master has confirmed that it suffered a data breach on May 19, allowing a threat actor to steal customer data. Cooler Master is a popular computer hardware manufacturer known for their cooling devices, computer ...
1 month ago Bleepingcomputer.com
I tried two passwordless password managers, and was seriously impressed by one - Password management apps have been around for decades. There's 1Password, for example, which promises that you'll only need to remember one password instead of dozens or hundreds. Also: Why you can still trust password managers, even after that ...
6 months ago Zdnet.com
Delta Dental of California Discloses Data Breach Impacting 6.9 Million People - Dental insurance giant Delta Dental of California is informing more than 6.9 million individuals that their personal information was compromised as result of the MOVEit hacking incident. In notification letters it started sending out last week to the ...
6 months ago Securityweek.com
CVE-2022-38142 - Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute ...
1 year ago
CVE-2022-41779 - Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would ...
1 year ago
CVE-2022-41778 - Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute ...
1 year ago
CVE-2023-1133 - Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which ...
1 year ago
CVE-2023-1139 - Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deserialization of requests prior to authentication, resulting in remote code ...
1 year ago
CVE-2023-1144 - Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation. ...
1 year ago
CVE-2023-1145 - Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote ...
1 year ago
CVE-2022-41644 - Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges. ...
1 year ago
CVE-2022-41629 - Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then ...
1 year ago

Latest Cyber News


Cyber Trends (last 7 days)


Trending Cyber News (last 7 days)