WAGO PFC200 Series

RISK EVALUATION. Successful exploitation of this vulnerability could allow an attacker with administrative privileges to access sensitive files in an unintended, undocumented way. Compact Controller CC100: Versions later than FW19, up to and including FW26. Edge Controller: Versions later than FW18, up to and including FW26. PFC100: Versions later than FW16, up to and including FW26. PFC200: Versions later than FW16, up to and including FW26. Touch Panel 600 Advanced Line: Versions later than FW16, up to and including FW26. Touch Panel 600 Marine Line: Versions later than FW16, up to and including FW26. Touch Panel 600 Standard Line: Versions later than FW16, up to and including FW26. 3.2 Vulnerability Overview. On affected Wago products a remote attacker with administrative privileges can access files which they already have access to through an undocumented local file inclusion. This access is logged in a different log file than expected. CVE-2023-4089 has been assigned to this vulnerability. A CVSS v3.1 base score of 2.7 has been calculated; the CVSS vector string is. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa. Gov/ics in the technical information paper, ICS-TIP-12-146-01B-Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

This Cyber News was published on www.cisa.gov. Publication date: Thu, 30 Nov 2023 21:55:05 +0000


Cyber News related to WAGO PFC200 Series

CVE-2022-22180 - An Improper Check for Unusual or Exceptional Conditions vulnerability in the processing of specific IPv6 packets on certain EX Series devices may lead to exhaustion of DMA memory causing a Denial of Service (DoS). Over time, exploitation of this ...
2 years ago
CVE-2022-0715 - A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT ...
11 months ago
CVE-2021-0207 - An improper interpretation conflict of certain data between certain software components within the Juniper Networks Junos OS devices does not allow certain traffic to pass through the device upon receipt from an ingress interface filtering certain ...
3 years ago
CVE-2019-0069 - On EX4600, QFX5100 Series, NFX Series, QFX10K Series, QFX5110, QFX5200 Series, QFX5110, QFX5200, QFX10K Series, vSRX, SRX1500, SRX4000 Series, vSRX, SRX1500, SRX4000, QFX5110, QFX5200, QFX10K Series, when the user uses console management port to ...
3 years ago
CVE-2021-0247 - A Race Condition (Concurrent Execution using Shared Resource with Improper Synchronization) vulnerability in the firewall process (dfwd) of Juniper Networks Junos OS allows an attacker to bypass the firewall rule sets applied to the input loopback ...
3 years ago
CVE-2021-0280 - Due to an Improper Initialization vulnerability in Juniper Networks Junos OS on PTX platforms and QFX10K Series with Paradise (PE) chipset-based line cards, ddos-protection configuration changes made from the CLI will not take effect as expected ...
2 years ago
CVE-2020-12506 - Improper Authentication vulnerability in WAGO 750-8XX series with FW version < FW03 allows an attacker to change the settings of the devices by sending specifically constructed requests without authentication This issue affects: WAGO 750-362, WAGO ...
2 years ago
CVE-2020-12505 - Improper Authentication vulnerability in WAGO 750-8XX series with FW version < FW07 allows an attacker to change some special parameters without authentication. This issue affects: WAGO 750-852, WAGO 750-880/xxx-xxx, WAGO 750-881, WAGO ...
2 years ago
CVE-2022-25155 - Use of Password Hash Instead of Password for Authentication vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series ...
10 months ago
CVE-2022-25157 - Use of Password Hash Instead of Password for Authentication vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series ...
10 months ago
CVE-2022-25158 - Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all ...
2 years ago
CVE-2022-25156 - Use of Weak Hash vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric ...
10 months ago
CVE-2021-20609 - Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions "24" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions "57" and prior, ...
1 year ago
CVE-2021-20610 - Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions "24" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions ...
1 year ago
CVE-2021-20611 - Improper Input Validation vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions "24" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions "57" and prior, ...
1 year ago
CVE-2019-5082 - An exploitable heap buffer overflow vulnerability exists in the iocheckd service I/O-Check functionality of WAGO PFC200 Firmware version 03.01.07(13), WAGO PFC200 Firmware version 03.00.39(12), and WAGO PFC100 Firmware version 03.00.39(12). A ...
4 years ago
CVE-2019-5074 - An exploitable stack buffer overflow vulnerability exists in the iocheckd service ''I/O-Check'' functionality of WAGO PFC200 Firmware version 03.01.07(13), WAGO PFC200 Firmware version 03.00.39(12) and WAGO PFC100 Firmware version ...
2 years ago
CVE-2021-0290 - Improper Handling of Exceptional Conditions in Ethernet interface frame processing of Juniper Networks Junos OS allows an attacker to send specially crafted frames over the local Ethernet segment, causing the interface to go into a down state, ...
2 years ago
CVE-2020-12522 - The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO Series PFC 100 (750-81xx/xxx-xxx), Series PFC 200 (750-82xx/xxx-xxx), Series Wago Touch Panel 600 Standard Line ...
3 years ago
CVE-2023-36850 - An Improper Validation of Specified Index, Position, or Offset in Input vulnerability in the Connectivity Fault Management(CFM) module of Juniper Networks Junos OS on MX Series(except MPC10, MPC11 and LC9600) allows an adjacent attacker on the local ...
11 months ago
CVE-2023-36848 - An Improper Handling of Undefined Values vulnerability in the periodic packet management daemon (PPMD) of Juniper Networks Junos OS on MX Series(except MPC10, MPC11 and LC9600) allows an unauthenticated adjacent attacker to cause a Denial of Service ...
6 months ago
CVE-2021-0235 - On SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3, vSRX Series devices using tenant services on Juniper Networks Junos OS, due to incorrect permission scheme assigned to tenant system administrators, a tenant system administrator ...
3 years ago
CVE-2024-2184 - Buffer overflow in identifier field of WSD probe request process of Small Office Multifunction Printers and Laser Printers(*) which may allow an attacker on the network segment to trigger the affected product being unresponsive or to execute ...
3 months ago Tenable.com
WAGO PFC200 Series - RISK EVALUATION. Successful exploitation of this vulnerability could allow an attacker with administrative privileges to access sensitive files in an unintended, undocumented way. Compact Controller CC100: Versions later than FW19, up to and ...
7 months ago Cisa.gov
CVE-2022-25159 - Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, ...
2 years ago

Latest Cyber News


Cyber Trends (last 7 days)


Trending Cyber News (last 7 days)